Olympus 190 egd scope diameter 9.9 mm. 180 diameter is 8.8 mm..
Reply to this Note | Notes Linking Here | 190 | 180 | Prior Note
Normal ampulla .
Common bile duct cannulation was performed using a Olympus sphincterotome .
Cholangiogram showed distal filling defects.
Sphincterotomy performed to 9 mm.
All stones extracted with Olympus balloon; [].
Normal occlusion cholangiogram at the end of the procedure. CPT Codes - 43261,43262,43264 in 2018